Duet wifi m307 I have a Duet 0. 519:0. ¶ Event System heater fault events. 4 D6. g file? here it is:; Configuration file for Duet WiFi (firmware version 3); executed by the firmware on start-up;; generated by RepRapFirmware Configuration Tool v3. g to match this. 02; RRF : v3. Did you have to use the adapter board for your hot end temp sensor? Mar 15, 2022 · My problem has changed since I last posted to one bad PT100 sensor. I typically had used DWC to interact with this printer. FBG. ¶ M143: Maximum heater temperature; M143 in RRF 3. x to RRF 3. There will be a separate video on that experience coming very soon, so make sure to be subscribed for that and have selected the notification bell. Example of machine with 1 motor for X, Y and Z, and 4 extruder motors: Sep 25, 2024 · It has a Duet 2, w/ v3. 3. 000 D7. 00 ; disable bang-bang mode for heater and set PWM limit M143 H1 S280 ; set temperature limit for heater 1 to 280C ; Tools M563 P0 D0 H1 F0 ; define tool 0 G10 P0 X0 Y0 Z0 Always use a cooling fan if you run a Duet 2 WiFi or Duet 2 Ethernet above 2. 0A motor current. This heater needs the following M307 command: Edit the M307 H0 command in config. The machine is a custom made printer: Board : Duet 2 wifi + Duex 5; Firmware : 3. 02 or later + DueX5 Board ID: 0JD0M-9P6M2-NW4SJ-6J9DD-3SJ6J-KASRK Used output buffers: 3 of 24 (16 max) You can temporarily increase the configured dead time for that heater. Not sure it matters . RRF3. 5, time constant 98. M80: ATX Power On. g Dec 29, 2016 · M307 H0 Heater 0 model: gain 361. 02 or later FIRMWARE_DATE: 2021-02-11. G2: Clockwise arc move. ¶ Assumptions. I recently bought a BlTouch clone (3D Touch) and I wanted to connect it to my duet 2 wifi installed on my Ender 3 but I can't get the probe to deploy. I am able to auto-tune heater at different part cooling fan speeds. 319:0. 03. 6 ELECTRONICS: Duet WiFi 1. G3: Counter On the Duet 3 MB6HC and MB6XD you can configure up to 4 chamber heaters; on Duet 3 Mini 5+, 2 chamber heaters; on Duet 2 WiFi/Ethernet, 4 chamber heaters; on Duet 2 Maestro, 2 chamber heaters. If necessary, use M307 to set some parameters that let you achieve a steady temperature. M911: Configure auto save on loss of power ¶ Motion ¶ Drives. x uses the GPIO concept extensively. 2, dead time 6. 00, mode: PID Duet WiFi hardware designer and firmware engineer Using that as an example, find the M307 H1 line in your config. 841 K0. For heater faults, the I am setting up a new Core XY build on a Duet Wifi Firmware is 3. 1 Aug 16, 2021 · M307 H0 B1 S1. 00 V24. 00 B0 M305 P0 T10000 B3988 C0 R4700 M143 H0 S120 M307 H1 A270. 21) ; executed by the firmware on start-up ; generated by RepRapFirmware Configuration Tool v2 on Mon Jan 07 2019 23:53:31 GMT+0200 (Eastern European Standard Time) Dec 4, 2019 · Newbie here to the duet wifi and reprap but im trying to get it configured on a custom 3d printer and im running into some issues… I was following this thread as a guide for some help… duet-wifi-independent-dual-x-y-axis-endstops-configuration/9787 my setup is basically: 2 motors x axis plugged into drive 0 and drive 4 (the Extruder 1 channel) 1 motor y, drive 1 2 motors z (to be used with Oct 27, 2020 · @ericlmccormick said in How to use a LED Strip with Duet 2 WiFI?: @the_dragonlord can you share your config. 50 B0 V23. 07 E1. 3 S1. 6 Config. 02 or later FIRMWARE_DATE: 2023-07-21 14:08:28 This is my config. a good starting point is the marlin configuration Hi I have a problem with Bltouchen I can not get it to work! Uses heater 3 Has an Ender 5 Plus with Micro swiss direct drive and bltouch X-50 Y-11. override. Nov 13, 2020 · RepRapFirmware for Duet 2 WiFi/Ethernet version 3. I'v connected the probe to pin 1, 2 and 31 and using Heater 7 and got nothing, as well as pin 1,2 and 8 for Heater 3. The printer is now controlled right from my PC using a web interface and wifi. If that works, and your Duet is under warranty, submit a warranty claim. Config. 5. ; Z-Probe Configuration file for Duet WiFi (firmware version 3); executed Jul 5, 2021 · RepRapFirmware for Duet 2 WiFi/Ethernet version 3. 1. 02 or later + DueX5 Firmware: RepRapFirmware for Duet 2 WiFi/Ethernet 2. 02 or later Firmware Version: 2. gcode is: M307 H0 A215. 16. 7 D5. g is like this. 0 C962. 2 firmware, and WiFi v1. This is great. 0 D5. Direct from the Duet using 24V power. M587: Add WiFi host network to remembered list, or list remembered networks. 3); executed by the firmware on start-up;; generated by RepRapFirmware Configuration Tool v3. 000, cooling rate 0. 4 on Sat Aug 10 2024 17:00:36 GMT-0400 (Eastern Daylight Time) ; General G90 ; absolute coordinates M83 ; relative extruder moves M550 P"M3ID V2" ; set hostname ; Accessories M575 P1 S0 Jan 29, 2021 · The BLTouch is connected to the PWM1 on the duex board and the two other wire are connected to the duet 2 on the "z probe in" PIN and the "GND" PIN. G0: Rapid move. 0, dead time 6. This document is relevant to: Duet 2 WiFi / Ethernet, Duet 2 Maestro, Duet 3 MB6HC and Duet 3 Mini 5+ Firmware versions: RepRapFirmware 3. M589: Configure access point parameters ¶ Power. I try auto-tunning, and play a lot with M307 settings, but nothing work : overshoot & unstable temperature (-7°, +13°) Duet : Duet WiFi 1. If I send the two M307 commands from your config. 00 ; disable bang-bang mode for the nozzle heater and set PWM limit: M307 H1 A475. 6 D4. (tried from 20% to 100% fan speed). 02 or later + DueX5 RepRapFirmware for Duet 2 WiFi/Ethernet 3. 6 with Firmware 1. 5 B0 to M307 H2 A340. file to confirm Im not doing and stupid even tho I thing I have tried every setting possible . I am currently trying to configure the heated bed. My questions are these, latest stable version to target for an install. 02 or later Board ID: 08DJM-9178L-L4MSJ-6J9F0-3S46Q-KT3YP Used output buffers: 3 of 24 (20 max) === RTOS === Static ram: 27980 Dynamic ram: 93884 of which 60 recycled Exception stack ram used: 304 Never used ram: 8844 Jan 2, 2019 · Hello, Duet Wifi board ver. 5, max PWM 1. 00, calibration voltage 24. x and and 2. 6 DWC I am wiring my probe as per (https: M307 H7 A-1 C-1 D-1. 02 and DWC is also latest version. It happens that the temperature is at 600 degrees Celcius. 006 D3. 4 on Mon Oct 26 2020 18:43:35 GMT+0100 (Ora standard dell’Europa I need help with a simple solution for heater faults. 2, max PWM 0. 3 D1. x is not plug-and-play. 10 on Sat Jan 08 2022 17:50:57 GMT+0100 (Midden-Europese standaardtijd); General preferences M575 P1 S1 B57600 ; enable support for PanelDue Nov 11, 2019 · Its Duet Wifi 2 on an Ender 3 could someone confirm their config. 0 and earlier ¶ Jul 4, 2024 · @ander A 'bad model parameters' is usually related to heater configuration. Set the heater to a temperature you typically use and wait until the temperature is stable. Jul 26, 2021 · Turn on at 50% if Driver temp reaches 45C, increase to full speed gradually as the temp rises to 55C. 001, dead time 2000. 1 Reply Last reply Reply Quote 0. 3, max PWM 1. From RepRapFrimware v3. 5 V24. 1 running on Duet WiFi 1. 7 C90. 8 S1. 8 C177. 24 No SBC. 3 B0 ; Disable bang-bang Jun 14, 2017 · Rostock Max V2, Duet Wifi, IR Probe, PanelDue 7" LCD, Heated Enclosure, Firestop cans, Thermally Fused 12v E3D V6, Berd Air, Floating Thermally fused 24v Bed, Aluminum heat spreader, PEI, Dual 12v PSUs in series. Giuliano Moschini has created a model based on the Duet 2 WiFi model for the Duet 2 Ethernet available here ¶ Physical connections ¶ Wiring diagram ¶ Revision v1. 2 ELECTRONICS: Duet WiFi 1. This is also for heater 0. 0 C140. g. @ericlmccormick said in How to use a LED Strip with Duet 2 WiFI?: In config. 22. 00, mode bang-bang Predicted max temperature rise 11°C The M307 using A, C and D parameters is from RRF 3. I’m working on modifying the Oct 27, 2020 · @ericlmccormick said in How to use a LED Strip with Duet 2 WiFI?: @the_dragonlord can you share your config. The default ones may work. 0 Dec 15, 2023 · M307 H0 A11 C99000 D2000 B1 M307 H0 Heater 0: heating rate 0. 4 on Mon Oct 26 2020 18:43:35 GMT+0100 (Ora standard dell’Europa Aug 13, 2024 · ; Configuration file for RepRapFirmware on Duet 3 Mini 5+ WiFi ; executed by the firmware on start-up ; ; generated by RepRapFirmware Configuration Tool v3. 23 undefined 1 Reply Last reply Reply Quote 0 A Former User @DanS79 Feb 1, 2019 · Firmware Name: RepRapFirmware for Duet 2 WiFi/Ethernet Firmware Electronics: Duet WiFi 1. 2 B0 Can I use heater outputs on duet wifi: M307 H0 A-1 C-1 D-1 ; disable heater on PWM channel for BLTouch - 1 elektromagnit M307 H1 A-1 C-1 D-1 ; disable heater on PWM channel for BLTouch - 1 elektromagnit and then M42 P0 s1 to switch on and M42 P0 S0 to switch off this is RRF 2 Mar 21, 2018 · Duet Wifi Version 1. Oct 25, 2024 · RepRapFirmware for Duet 2 WiFi/Ethernet version 3. I'm considering the Duet 2 WiFi for my S5 with a Bondtech DDS and BLTouch. 02RC7(RTOS) (2018-12-22b2) WiFi Server Version: 1. 1 on Sat Feb 24 2024 20:38:01 GMT-0600 (Central Standard Time) ; General preferences G90 ; send absolute coordinates Jan 13, 2021 · ; Configuration file for Duet WiFi (firmware version 3); executed by the firmware on start-up;; generated by RepRapFirmware Configuration Tool v3. 5 D0. Where a FIRMWARE_NAME: RepRapFirmware for Duet 2 WiFi/Ethernet FIRMWARE_VERSION: 3. 35 S1. 0 and earlier ¶ @Tinchus if the model parameters don't work with your heated chamber then you might need to revert to bang-bang control. 083 K1. 00 ; enable bang-bang mode for the bed heater and set PWM limit Home-built CoreXY, Duet Wifi, Chimera direct drive, 2x BMG, 300x300x300 build volume Nov 11, 2023 · I am using a Duet 2 WiFi/Ethernet board and a RRF version 2. The message and the written lines are inconsistent. 05 (2019-12-13b1) Duet WiFi Server Version: 1. 3) ; executed by the firmware on start-up ; ; generated by RepRapFirmware Configuration Tool v3. 00 B0 V23. I may update that all in the future, but for now I'm using it to better match my config file version made by the RRF tool. The result of an heater auto-tune provides a prototype line for inclusion in a config, or use M500 to write into config-override. Sep 8, 2024 · Auto tuning heater 0 completed after 4 idle and 25 tuning cycles in 1620 seconds. 4 and later) On Duet 2 WiFi/Ethernet, there is an endstop status LED between each motor driver. 0 S0. Jan 17, 2019 · Just wanted to post this quick video I took of my Taz 6 which is now running off a Duet Wifi Mainboard, a Pitan extruder available on thingiverse and a BL-Touch for bed leveling. g ;LED Strip M950 P2 C"e1heat" M307 P2 A-1 C-1 D-1 Then add the following to ch Mar 27, 2021 · Over the last week, I’ve been putting the new DUET 3 Mini 5+ control board into my old Prusa Mk2. 1. 00, max PWM 1. 21 Web Interface Version: 1. There are significant configuration differences from version 2, so upgrading from RRF 2. 5, where the plugs of the control board burnt out. The current RRF version can usually take settings from older versions of M307 and convert them to the current parameters. 1; BLTouch : 3. 58 E1. The command M307 H4 A-1 C-1 D-1 in your config. 6, time constant 647. 00 ; enable bang-bang mode for the bed heater and set PWM limit M140 H0 ; map heated bed to heater 0 Configuration file for Duet WiFi (firmware Oct 27, 2020 · @ericlmccormick said in How to use a LED Strip with Duet 2 WiFI?: @the_dragonlord can you share your config. PID control doesn't really work when Mar 20, 2021 · My duet wifi board is 1. The wiring and the 100k thermistors are all good. I have upgraded my tronxy x5s with an duet 2 ethernet, but i can't figure out how to fix the temperature readings. so my bed has been working fine with those settings above and the results were not much different . M307 H1 Heater 1 model: gain 336. g and adjust it as follows, using the values for gain, time constant, dead time, and voltage from your M307 output M307 H1 A199. Hey I installed a bltouch on my duetwifi, and it deploys and retracts when i turn the machine on but does not respond to m401 or m402, I have looked at the setup page and the troubleshooting page and I feel like I made a huge mistake somewhere. M588: Forget WiFi host network. g file has a different purpose, it disables Heater 4 in order to make its output pin free to use as the BLTouch control pin, so that M280 commands can use it. 21 RC5. It’s amazing how much quieter the printer is due to the higher microstepping from the Duet Wifi board. The Panel Due is v1. The b Apr 17, 2020 · M307 H1 B0 S1. Jan 9, 2020 · M307 H7 A-1 C-1 D-1 ; Disable the 7th Heater to free up PWM channel 5 on the Duex board. 0 Jan 9, 2023 · I'm upgrading a professional 3D printer (Intamsys Funmat HT) with a Duet 2 Wifi controller and have a lot of problem with hotend temperature. 02 or later Board ID: 0JD0M-9P6M2-NW4SN-6J1DG-3SD6J-TUT3L Used output buffers: 1 of 26 (2 max) === RTOS === Static ram: 23896 Dynamic ram: 75148 of which 0 recycled Never used RAM 12964, free system stack 134 words ; Configuration file for Duet WiFi (firmware version 3. 2, dead time 9. When I first started up the newly flashed system I was able to heat up the hotend to 50 C before I got a heater fault. 3 (2021-06-15 21:44:54) running on Duet WiFi 1. I need a little help from my friends. 25. I'm riding a Voron 2 using RevoVoron hotend, Duet2 wifi and RepRap Firmware. 05. Aug 20, 2018 · Duet WiFi hardware designer and firmware engineer Once the tuning has completed successfully, you need to use M307 to add the A, C and D paramters into you Jan 7, 2020 · Hypercube-Evolution-Hybrid, Piezo Orion, Orbiter Duet WiFi 1. undefined. M307 H1 A216. A quick update: I rolled back the firmware on my Duet 2 wifi to 2. 0 on Sat Jan 02 2021 15:54:53 GMT+1100 (Australian Eastern Daylight Time) Dec 18, 2023 · FIRMWARE_NAME: RepRapFirmware for Duet 2 WiFi/Ethernet FIRMWARE_VERSION: 3. The bad sensor now reads in the 500s only. Panel Due with firmware 1. 046 K1. G1: Controlled *(linear) move. For example, sending M307 H0 D60 before sending the M303 tuning command will increase the heater 0 dead time to 60 seconds. 7 C711. g : Jan 23, 2021 · @Veti said in Artillery Genius Duet 2 Wifi Configuration: @d0minik96 said in Artillery Genius Duet 2 Wifi Configuration: I cant find any Informations about the Spindle used in the genius and the sensor in the heated bed for example. ¶ 3D models. 9 Warning: M307: Heater 1 predicted maximum temperature at full ; Duet 2 ; Heaters M308 S1 P"e0temp" Y"thermistor" T100000 B4725 C7. 2. 27; PT100 daughterboard Jan 17, 2018 · Change M307 H1 A340. GitHub Gist: instantly share code, notes, and snippets. And DWC 1. 0beta4 (2021-09-27 11:30:36) ; Configuration file for Duet WiFi (firmware version 3. Phil Maddox has created a 3d model of the Duet 2 WiFi available here. I keep having the error: Temperature reading fault on heater 1: unknown temperature sensor channel. M307 H1 R7. 02 Z0 Anyo Feb 8, 2021 · Board: Duet WiFi 1. 02 or later electronics firmare and 2. g, I get the following response: M307 H0 R0. 9 (RRF 3. 35 S0. 060000e-8 R4700 to M305 P1 P2 T100000 B4725 C7. 5; WiFi firmware : 1. 4 on Mon Oct 26 2020 18:43:35 GMT+0100 (Ora standard dell’Europa Jan 7, 2018 · Duet WiFi hardware designer and firmware engineer M307 H1 Heater 1 model: gain 1001. 03 firmware with 1. Your guidance is kindly requested. M81: ATX Power Off. 1 ¶ Overview. 15a. 1 original; That's my config. 060000e-8 R4700; Change M563 P0 D0 H1 to M563 P0 D0 H2; 4. Also using the TP100 daughterboard. 4. 2, time constant 308. 7 B0 S1. 06e-8 ; configure sensor 1 as thermistor on pin e0temp M950 H1 C"e0heat" T1 ; create nozzle heater output on e0heat and map it to sensor 1 M307 H1 B0 S1. 5 B0; Change M305 P1 T100000 B4725 C7. 00 M140 H0 M143 H0 S100 M308 S0 P"temp0" Y"thermistor" T100000 B4138 Home-built CoreXY, Duet Wifi, Chimera direct drive, 2x BMG, 300x300x300 build RepRapFirmware 3 is the next generation version of RepRapFirmware for Duet 3, Duet 2 WiFi/Ethernet/Maestro, and some other 32-bit motion control electronics. 00 B0 Error: M307: bad model parameters: estimated temperature rise too small M307 H1 R3. 1 B0 ; PID Auto tune values; Sensors for MCU thermal fans: M308 S3 Y"mcu-temp" A"MCUTemp" ; configure sensor 3 as thermistor on pin mcu-temp for Duet 2 Feb 27, 2021 · M307 H0 B1 S1. 50 Duet 2 boards with an expansion board (DueX2/5, Expansion Breakout Board or external driver for Duet 2 WiFi/Ethernet, and Dual Stepper Driver Expansion Module for Duet 2 Maestro) simply continues the motor numbering. Apr 18, 2020 · ; Configuration file for Duet WiFi (firmware version 1. 57 V24. The RevoVoron sensor is connected in E0 Thermistor 1 and the Heater is connected in E0 Heater. 6 (2023-07-21 14:08:28) running on Duet WiFi 1. With the Duet 2s this is suitable up to 24 * 18 = 432W heating power. The probe does the self test at boot but after that nothing. g: Hi, I am using a 50W heater with Biqu H2 extruder. upgrade path, full jump in version or steps, sequence of upgrades , duet, wifi, and panel. The Duet 2 (Wifi and Ethernet) is rated for up to 18A bed heater current, so this is suitable up to 12 * 18 = 216W power. 000 D5 E1. 0 C139. See Configuring stepper motors. 473:0. Your laser runs on 12v; Your laser requires a 5v active-high PWM May 23, 2021 · M307 H0 B1 S1. Omit the V parameter if the heater is not powered from VIN. 18. 01 and later; M143 in RRF 3. 0-3. This guide covers connecting and configuring a PWM-driven laser module to Duet 2 and Duet 3 boards. On the Duet 3 MB6HC and MB6XD you can configure up to 4 chamber heaters; on Duet 3 Mini 5+, 2 chamber heaters; on Duet 2 WiFi/Ethernet, 4 chamber heaters; on Duet 2 Maestro, 2 chamber heaters. 4 errors can be reported and handled through the Event System. Because of this the temperature reading are 2000C. bvtyv xor dannj ifwu rxts kacaw oeuppfq wlb yyx gnyvn